The Z2S-LM are high performance digital force gauges that feature a separate sensor that is ideal for confined spaces or difficult to reach measurements. All standard LM sensors are less than 1.5" in both diameter and height and measure compression only. A standard six foot cable connects the gauge to the sensor.
The Z2S-LM unit offers programmable high/low setpoints for go/no-go testing. ORANGE lights up for measurements less than Low setpoint, GREEN for between High and Low setpoint, and RED for over High setpoint.
Store up to 1,000 values in memory, which can be displayed or transmitted using the RS-232C port. Use the real time mode to display load transients, or the peak mode to capture the peak force achieved during a test. Selectable measuring units of lbf, kgf, or Newtons.
- LM button sensors are less than 1.5" in both diameter and height and measure compression only
- Programmable high/low setpoints with color-coded LED indicators and output signal for quick go/no go testing
- 1,000 Data memory for computer download
- Reversible display
- lbf, kgf, and N units are push button selectable
- RS-232C, Digimatic and Analog outputs
- Runs on internal Ni-MH batteries or AC adapter
- Ergonomic design with non-slip rubber grip, heavy duty metal construction
- Overload capacity 200% of F.S. (push/pull)
- Real time and peak mode (selectable)
- Overload indicator and output signal
- Low battery indicator
- External switch display hold and clear
- Includes 6 cable, AC adapter/charger and carrying case
Warranty Information
Z2S-LM Specifications |
Accuracy
|
±0.5% ±1 LSD
|
Selectable Units
|
Pounds, Kilograms or Newtons
|
Overload Capacity
|
200% of F.S. (Overload indicator flashes beyond 108% of
F.S.)
|
Power
|
Rechargeable Ni-MH battery pack or AC adapter
|
Low Battery Indicator
|
Battery icon flashes when battery is low
|
Memory
|
Non-volatile, recall up to 1,000 loads
|
Setpoints
|
Programmable high/low setpoints with color-coded
indicators and output signal
|
Outputs
|
RS-232C, Digimatic and ±2 VDC analog output
|
Operating Temp.
|
32° to 100°F (0° to 40°C)
|
Z2S-LM Ranges (Resolution) Accuracy: ±0.5% F.S. ±1 LSD
|
Model |
Capacity
(Resolution)
|
|
|
Pounds/Ounces
|
Kilograms/Grams
|
Newtons
|
Z2S-LM-1
|
18.00 (0.01 ozf)
|
500.0 (0.1 gf)
|
5.000 (0.001 N)
|
Z2S-LM-4
|
4.400 (0.001 lbf)
|
2.000 (0.001 kgf)
|
20.00 (0.01 N)
|
Z2S-LM-11
|
11.00 (0.01 lbf)
|
5.000 (0.001 kgf)
|
50.00 (0.01 N)
|
Z2S-LM-44
|
44.00 (0.01 lbf)
|
20.00 (0.01 kgf)
|
200.0 (0.1 N)
|
Z2S-LM-110
|
110.0 (0.1 lbf)
|
50.00 (0.01 kgf)
|
500.0 (0.1 N)
|
Z2S-LM-220
|
220.0 (0.1 lbf)
|
100.0 (0.1kgf)
|
1000 (1N)
|
Z2S-LM-440
|
440.0 (0.1 lbf)
|
200.0 (0.1kgf)
|
2000 (1N)
|
Z2S-LM-1100
|
1100 (1 lbf)
|
500.0 (0.1kgf)
|
5000 (1N)
|
Z2S-LM-2200
|
2200 (1 lbf)
|
1000 (1kgf)
|
10.00 (0.01KN)
|
Z2S-LM-4400
|
4400 (1 lbf)
|
2000 (1kgf)
|
20.00 (0.01KN)
|